| #include <furi.h>
 | |
| #include <furi_hal.h>
 | |
| #include "../minunit.h"
 | |
| 
 | |
| static void power_test_deinit(void) {
 | |
|     // Try to reset to default charging voltage
 | |
|     furi_hal_power_set_battery_charging_voltage(4.208f);
 | |
| }
 | |
| 
 | |
| MU_TEST(test_power_charge_voltage_exact) {
 | |
|     // Power of 16mV charge voltages get applied exactly
 | |
|     // (bq25896 charge controller works in 16mV increments)
 | |
|     //
 | |
|     // This test may need adapted if other charge controllers are used in the future.
 | |
|     for(uint16_t charge_mv = 3840; charge_mv <= 4208; charge_mv += 16) {
 | |
|         float charge_volt = (float)charge_mv / 1000.0f;
 | |
|         furi_hal_power_set_battery_charging_voltage(charge_volt);
 | |
|         mu_assert_double_eq(charge_volt, furi_hal_power_get_battery_charging_voltage());
 | |
|     }
 | |
| }
 | |
| 
 | |
| MU_TEST(test_power_charge_voltage_floating_imprecision) {
 | |
|     // 4.016f should act as 4.016 V, even with floating point imprecision
 | |
|     furi_hal_power_set_battery_charging_voltage(4.016f);
 | |
|     mu_assert_double_eq(4.016f, furi_hal_power_get_battery_charging_voltage());
 | |
| }
 | |
| 
 | |
| MU_TEST(test_power_charge_voltage_inexact) {
 | |
|     // Charge voltages that are not power of 16mV get truncated down
 | |
|     furi_hal_power_set_battery_charging_voltage(3.841f);
 | |
|     mu_assert_double_eq(3.840, furi_hal_power_get_battery_charging_voltage());
 | |
| 
 | |
|     furi_hal_power_set_battery_charging_voltage(3.900f);
 | |
|     mu_assert_double_eq(3.888, furi_hal_power_get_battery_charging_voltage());
 | |
| 
 | |
|     furi_hal_power_set_battery_charging_voltage(4.200f);
 | |
|     mu_assert_double_eq(4.192, furi_hal_power_get_battery_charging_voltage());
 | |
| }
 | |
| 
 | |
| MU_TEST(test_power_charge_voltage_invalid_clamped) {
 | |
|     // Out-of-range charge voltages get clamped to 3.840 V and 4.208 V
 | |
|     furi_hal_power_set_battery_charging_voltage(3.808f);
 | |
|     mu_assert_double_eq(3.840, furi_hal_power_get_battery_charging_voltage());
 | |
| 
 | |
|     // NOTE: Intentionally picking a small increment above 4.208 V to reduce the risk of an
 | |
|     // unhappy battery if this fails.
 | |
|     furi_hal_power_set_battery_charging_voltage(4.240f);
 | |
|     mu_assert_double_eq(4.208, furi_hal_power_get_battery_charging_voltage());
 | |
| }
 | |
| 
 | |
| MU_TEST_SUITE(test_power_suite) {
 | |
|     MU_RUN_TEST(test_power_charge_voltage_exact);
 | |
|     MU_RUN_TEST(test_power_charge_voltage_floating_imprecision);
 | |
|     MU_RUN_TEST(test_power_charge_voltage_inexact);
 | |
|     MU_RUN_TEST(test_power_charge_voltage_invalid_clamped);
 | |
|     power_test_deinit();
 | |
| }
 | |
| 
 | |
| int run_minunit_test_power() {
 | |
|     MU_RUN_SUITE(test_power_suite);
 | |
|     return MU_EXIT_CODE;
 | |
| }
 | 