* FuriHal: refactor power gauge config * Format sources and move gauge DM load to separate method * FuriHal: bq27220 refactoring part 1 * Power: use SYSDWN battery status flag for system shutdown * Libs: bq27220 read DM before write, fix incorrect shift * FuriHal: cleanup gauge config, add flags, add ptr DM type, update symbols * FuriHal: 2 stage gauge DM verification and update, better detection routine * FuriHal: update gauge configuration, lower sleep current and deadband * FuriHal: gauge and charger health reporting * Lib: cleanup bq27220 sources * FuriHal: correct documentation for furi_hal_power_is_shutdown_requested * FuriHal: proper gauge config for f7
		
			
				
	
	
		
			93 lines
		
	
	
		
			3.4 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
			
		
		
	
	
			93 lines
		
	
	
		
			3.4 KiB
		
	
	
	
		
			C
		
	
	
	
	
	
#pragma once
 | 
						|
 | 
						|
#include <stdint.h>
 | 
						|
#include <stdbool.h>
 | 
						|
#include <furi_hal_i2c.h>
 | 
						|
 | 
						|
#define BQ27220_ERROR 0x0
 | 
						|
#define BQ27220_SUCCESS 0x1
 | 
						|
 | 
						|
typedef struct {
 | 
						|
    // Low byte, Low bit first
 | 
						|
    bool DSG : 1; // The device is in DISCHARGE
 | 
						|
    bool SYSDWN : 1; // System down bit indicating the system should shut down
 | 
						|
    bool TDA : 1; // Terminate Discharge Alarm
 | 
						|
    bool BATTPRES : 1; // Battery Present detected
 | 
						|
    bool AUTH_GD : 1; // Detect inserted battery
 | 
						|
    bool OCVGD : 1; // Good OCV measurement taken
 | 
						|
    bool TCA : 1; // Terminate Charge Alarm
 | 
						|
    bool RSVD : 1; // Reserved
 | 
						|
    // High byte, Low bit first
 | 
						|
    bool CHGINH : 1; // Charge inhibit
 | 
						|
    bool FC : 1; // Full-charged is detected
 | 
						|
    bool OTD : 1; // Overtemperature in discharge condition is detected
 | 
						|
    bool OTC : 1; // Overtemperature in charge condition is detected
 | 
						|
    bool SLEEP : 1; // Device is operating in SLEEP mode when set
 | 
						|
    bool OCVFAIL : 1; // Status bit indicating that the OCV reading failed due to current
 | 
						|
    bool OCVCOMP : 1; // An OCV measurement update is complete
 | 
						|
    bool FD : 1; // Full-discharge is detected
 | 
						|
} BatteryStatus;
 | 
						|
 | 
						|
_Static_assert(sizeof(BatteryStatus) == 2, "Incorrect structure size");
 | 
						|
 | 
						|
typedef struct {
 | 
						|
    // Low byte, Low bit first
 | 
						|
    bool CALMD : 1; /**< Calibration mode enabled */
 | 
						|
    uint8_t SEC : 2; /**< Current security access */
 | 
						|
    bool EDV2 : 1; /**< EDV2 threshold exceeded */
 | 
						|
    bool VDQ : 1; /**< Indicates if Current discharge cycle is NOT qualified or qualified for an FCC updated */
 | 
						|
    bool INITCOMP : 1; /**< gauge initialization is complete */
 | 
						|
    bool SMTH : 1; /**< RemainingCapacity is scaled by smooth engine */
 | 
						|
    bool BTPINT : 1; /**< BTP threshold has been crossed */
 | 
						|
    // High byte, Low bit first
 | 
						|
    uint8_t RSVD1 : 2;
 | 
						|
    bool CFGUPDATE : 1; /**< Gauge is in CONFIG UPDATE mode */
 | 
						|
    uint8_t RSVD0 : 5;
 | 
						|
} OperationStatus;
 | 
						|
 | 
						|
_Static_assert(sizeof(OperationStatus) == 2, "Incorrect structure size");
 | 
						|
 | 
						|
typedef struct BQ27220DMData BQ27220DMData;
 | 
						|
 | 
						|
/** Initialize Driver
 | 
						|
 * @return true on success, false otherwise
 | 
						|
 */
 | 
						|
bool bq27220_init(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
/** Initialize Driver
 | 
						|
 * @return true on success, false otherwise
 | 
						|
 */
 | 
						|
bool bq27220_apply_data_memory(FuriHalI2cBusHandle* handle, const BQ27220DMData* data_memory);
 | 
						|
 | 
						|
/** Get battery voltage in mV or error */
 | 
						|
uint16_t bq27220_get_voltage(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
/** Get current in mA or error*/
 | 
						|
int16_t bq27220_get_current(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
/** Get battery status */
 | 
						|
bool bq27220_get_battery_status(FuriHalI2cBusHandle* handle, BatteryStatus* battery_status);
 | 
						|
 | 
						|
/** Get operation status */
 | 
						|
bool bq27220_get_operation_status(FuriHalI2cBusHandle* handle, OperationStatus* operation_status);
 | 
						|
 | 
						|
/** Get temperature in units of 0.1°K */
 | 
						|
uint16_t bq27220_get_temperature(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
/** Get compensated full charge capacity in in mAh */
 | 
						|
uint16_t bq27220_get_full_charge_capacity(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
/** Get design capacity in mAh */
 | 
						|
uint16_t bq27220_get_design_capacity(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
/** Get remaining capacity in in mAh */
 | 
						|
uint16_t bq27220_get_remaining_capacity(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
/** Get predicted remaining battery capacity in percents */
 | 
						|
uint16_t bq27220_get_state_of_charge(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
/** Get ratio of full charge capacity over design capacity in percents */
 | 
						|
uint16_t bq27220_get_state_of_health(FuriHalI2cBusHandle* handle);
 | 
						|
 | 
						|
void bq27220_change_design_capacity(FuriHalI2cBusHandle* handle, uint16_t capacity);
 |